Thursday, April 21, 2011

Residential, Large Solar PV Installation - Meyersdal

Photos taken during final stages of installation and initial commissioning of the system.
This is a new development, home.
Specs on the system:
  1. Design by InSynch and AM Solar.
  2. PV Bank = 24 x 210w Sanyo Solar Panels.
  3. Battery Bank = 24 x 1200AH Tubular Cell 2v Cells (Raylite).
  4. Inverters = 2 x 3kw Grid-Tied Outback FX Inverter/Chargers (in parallel).
  5. Charge Controllers = 2 x Outback FM80's and 1 x MX60.
  6. Protection = multi DC circuit breakers and fuses. Note these are 100% DC breakers, not AC breakers with a DC rating. A common mistake made by our competitors.
  7. Communications = Outback MATE2 and HUB10.
  8. Load: +- 70% of the home is off-grid.
  9. Backup = ESKOM grid connection
  10. Commissioning and Operator training and manual = AM Solar - Professional Solar Solutions and Off-Grid Energy Specialists.
























Pavillion Dalrymple - Rammed Earth Wall (Top Floor)

This is the ground floor or top storey to the Pavillion.
The feature Rammed Earth wall has the following specs:
1. Stabilised with Lime (10%).
2. User +- 7 different colour mixes from 4 separate soil colour deposits.
3. Length of Wall = 27m.
4. Height of Wall = 5.5m (including basement wall = 8.5m).
5. Width of Wall = varies from 150mm to 550mm.
6. Hand rammed.
Enjoy. It was an awesome project fro InSynch.

Architects: Silvio Rech and Leslie Carstens


























This is the bottom wall, now with some of the fixtures added.
Insych are just doing some last minute touch ups.